KRAL measurement-devices from the OME flow meters in all design sizes always measure in both flow directions. This is made possible by the 3-in-1-sensors, which detect a change in the flow direction automatically and very fast. Another advantage is the integrated Pt100 temperature sensor, which also measures the temperature of the medium.
Technical data | OME-13 | OME-20 | OME-32 | OME-52 | |
---|---|---|---|---|---|
Nominal diameter | DN [mm] | 15 | 20 | 25/32 | 40 |
DN [inch] | 1/2 | 3/4 | 1 | 1 1/2 | |
Total length with DIN flange | [mm] | 105 | 135 | 185 | 325 |
Weight with DIN flange | [kg] | 2 | 2 | 4 | 12 |
Flow rate I/h | Qmax | 900 | 2,700 | 9,000 | 31,500 |
Qnom | 600 | 1,800 | 6,000 | 21,000 | |
Qmin | 6 | 18 | 60 | 210 | |
Flow rate I/min | Qmax | 15 | 45 | 150 | 525 |
Qnom | 10 | 30 | 100 | 350 | |
Qmin | 0.1 | 0.3 | 1.0 | 3.5 | |
Max. pressure | [bar] | 40 | 40 | 40 | 40 |
Temperature | [°C] | -20 to +125 | -20 to +125 | -20 to +125 | -20 to +125 |
Viscosity | [mm²/s] | 1 to 1×106 | 1 to 1×106 | 1 to 1×106 | 1 to 1×106 |
Precision | of measurement value | ±0.1 % | ±0.1 % | ±0.1 % | ±0.1 % |
Repeatability | ±0.01 % | ±0.01 % | ±0.01 % | ±0.01 % | |
K-factor | K [P/I] | 1,214.0 | 321.0 | 78.0 | 17.73 |
Frequency | f at Qnom [Hz] | 202 | 161 | 130 | 104 |